GAS, FIRE, HEAT & SMOKE DETECTION EQUIPMENT
|
|
 |
IMPACT / IMPACT PRO PERSONAL MULTIGAS MONITORS
Zones 0, 1 & 2 Intrinsically Safe
|
- ATEX Ex II 1G, EExia d IIC T4
- Instrument IP65. Cartridge IP54.
- Certified Temperature: -20C to +55C
- Material: Impact Resistant Plastic
- Impact Model Detects: Flammable Gas, O2, CO, H2S
- Impact Pro Model Detects: Flammable Gas, O2, CO, H2S, SO2, CL2, CIO2, NO2, NH3, CO2.
- Features Audible Alarm, Visual Alarm, intuitive menu, multi-lingual.
|
|
|
|
 |
IMPULSE XP
DISPOSABLE SINGLE GAS DETECTOR
Zones 0, 1 & 2
Intrinsically Safe
|
- ATEX Ex II 1G, EEx ia IIC T4
- IP54.
- Operating Temperature: -20C to +50C
- Max operating life: 2 years after activation
- Detects: O2, CO, H2S
- Features Audible Alarm - 95db @10cm, Visual Alarm - high density
red LEDs, vibrating alarm, custom LCD display.
- Dimensions:87x50x27mm
- Weight: CO/H2S 73g O2 73g
|
|
|
|
 |
APEX GAS DETECTOR TRANSMITTER
Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd ia IIC
- IP66/67.
- Certified Temperature: -40C to +65C
- 24Vdc nominal (18-32Vdc)
- Stainless Steel 316 enclosure
- Operating Humidity: 0-99% (non-condensing)
- 3 fully configurable relay outputs and an isolated 4-20mA signal.
- Choice of digital output protocols.
- Detects over 40 toxic gases and a wide range of flammable gases
|
|
|
|
 |
SENSEPOINT TOXIC GAS SENSORS
Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd ia IIC T4.
- IP65 as standard. IP66/67 with weather protection.
- Certified Temperature: -55C to +60C
- Voltage: 18 to 30Vdc, 0.9W maximum.
- Material: PPS
- Signal Output: Loop powered 4 to 20mA
- Operating Pressure: 90 to 110kPa
- Humidity 20-90% (continuous),
10 to 99% (intermittent).
- Detects C0, CL2, SO2, O2, NO2, NO, NH2, H2S, H2.
|
|
|
|
 |
SENSEPOINT COMBUSTIBLE GAS SENSORS
LEL or PPM Detection
Zones 1 & 2 Flameproof
|
- LEL: ATEX Ex II 2G, EExd IIC T3-T6.
- PPM: ATEX Ex II 2G, EExd IIC T5-T6.
- IP65 as standard. IP66/67 with weather protection.
- LEL: Certified Temperature: -55C to +60C or -55C to +150C
- PPM: -30C to +65C
- Material: Polyphenylene sulfide (PPS).
- Supply: 200mA: 0.7W max
- Signal Output: mV Bridge
- Operating Pressure: 90 to 110kPa
|
|
|
|
 |
OPTIMA PLUS
Infrared Point Gas Detector
Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd IIC T4 or T5.
- IP66/67
- Certified Temperature: -40C to +65C
- 18-32V (24V nominal)DC, <4.5W max.
- Fast speed of access
- Dual channel, fully compensated infrared optical configuration.
- Failsafe Operation.
|
|
|
|  |
SEARCHFLAME 16 UV/IR OPTICAL FLAME DETECTOR
Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd IIB + H2 T5.
- IP66
- Certified Temperature: -40C to +85C
- Material: Copper-free aluminium with powder coat finish or stainless steel.
- Voltage: 24Vdc nominal. 56mA typical normal operation; 68mA typical fire conditions.
- Operating Pressure: 90 to 100kPa
- Relay Outputs: Fire, verification, fault.
Analogue Output: 0 to 20m(A) option
|
|
|
|
 
HDI
HEAT DETECTOR
Zones 0, 1 & 2
Intrinsically Safe, Increased Safety,Flameproof.
|
- ATEX Ex II 1G, EExia IIC T6
- ATEX Ex II 2G, EExd IIB T6, EExem II T6.
- IP66/67
- Certified Temperature: EExia -55C to +55C
- Certified Temperature: EExd/EExem -20C to +55C
- EExia: 30V, 300mA.
- EExd I EExem: 125Vac (5A), 125Vac (0.5A), 48Vdc (1A)
|
|
|
|
 |
DCD-1E-IS HEAT DETECTOR Conventional 'Rate of Rise' Detector
Zones 0, 1 & 2 Intrinsically Safe
|
- ATEX Ex II 1G, EExia IIC T6 Ta 55C
- Certified Temperature: -10C to +55C
- Polycarbonate (Ivory White) enclosure
- 15-30Vdc.
- Alarm State Current: (at 24Vdc): 50mA (max)
- 60°C fixed temperature element
- Twin fire LED’s allow 360º viewing
|
|
|
|
 |
SLR-E-IS SMOKE DETECTOR
Conventional Optical Detector
Zones 0, 1 & 2 Intrinsically Safe
|
- ATEX Ex II 1G, EExia IIC T5 Ta 55C
- Certified Temperature: -10C to +55C
- ABS (Ivory White) enclosure.
- 15-30Vdc.
- Alarm State Current: (at 24Vdc): 50mA (max)
- Twin fire LED’s allow 360º viewing.
|
|
| |