FLUORESCENT LIGHTING
|
|
|
ELLK 92
Zones 1, 2, 21 & 22 Increased Safety, Flameproof Standard or Emergency
|
- ATEX Ex II 2GD, EExed ib IIC T4 / EExedm ib IIC T4
- IP66
- Standard Certified Temperature: -20C to +50C (+40C for 2 x 58W)
- Emergency Certified Temperature: -5C to +50C
- Single or twin options: 18, 36 or 58W
- Standard: 110-254 Vac or 110-230 Vdc
- Standard 2 x 58W: 220-254 Vac or 220-230 Vdc
- Emergency: 220-254 Vac
- Polyester reinforced enclosure, polycarbonate protective bowl.
|
|
|
|
|
TRIDENT VL125 & VL126
Zones 1, 2, 21 & 22 Increased Safety Standard or Emergency
|
- ATEX Ex II 2GD, EExem II T4
- Up to IP68
- Standard Certified Temperature: -45C to +55C (+50C for 58W)
- Emergency Certified Temperature: -15C to +55C (+50C for 58W)
- Twin 18, 36 or 58W
- Standard & Emergency: 220-254V, 47/63 Hz ac/dc
- Polycarbonate moulded enclosure with stainless steel reflector
|
|
|
|
|
SERIES 7 COMPACT
Zones 1, 2, 21 & 22 Flameproof Standard or Emergency
|
- ATEX Ex II 2G (D for glass only), EExd IIC T4-T6
- IP66
- Certified Temperature: -25C to +55C
- Standard Single or Twin 11,18, 26, 36 or 55W
- Emergency Single 18W or single/twin 26W
- Standard & Emergency: 240V, 50/60 Hz
- Corrosion resistant anodised light alloy body and covers.
- Polycarbonate overtube.
|
|
|
|
|
SERIES 7
Zones 1 & 2 Flameproof Standard or Emergency
|
- ATEX Ex II 2G, EExd IIB & IIC T4-T6
- IP66
- Certified Temperature: -25C to +55C
- Standard Single 8, 18, 36, 58 or 70W
- Emergency Single 8, 18, 36 OR 58W
- Standard & Emergency: 240V 50 Hz
- Corrosion resistant anodised light alloy body and covers, polycarbonate overtube
|
|
|
|
|
SERIES 9
Zones 1 & 2 Increased Safety, Flameproof Standard or Emergency
|
- ATEX Ex II 2G, EExed IIC T4/T5
- IP66
- Certified Temperature: T4 @ ta 55C, T5 @ Ta 25C
- Standard Twin 18, 36 or 58W
- Emergency Twin 18, 36 OR 58W
- Standard & Emergency: 220-250V 50/60 Hz or 110-130V 50/60 Hz
- Aluminium body with polycarbonate overtube
|
|
|
|
|
094 SERIES CYLINDRICAL
Zones 1,2,21 & 22 Safety, Flameproof
|
- ATEX 0081 Ex II 2GD, EExd IIC/IIB T5/T6
- IP66 & IP67
- Certified Temperature: -20C to +40C
- Single or Twin
- Standard & Compact Models
- Electronic Ballast
- Zamak painted (grey) end cap & cover.
- Borosillicate overtube.
|
|
|
|

096 SERIES
Zones 1, 2, 21 & 22
Increased Safety
Standard or Emergency
|
- ATEX 6004-06 Ex II 2G, 2D 85C, EExed or EExedm IIC T4-T5
- IP66 & IP67
- Certified Temperature: -20C to +55C Range
- 110/127V and 220/240V Options
- Fibreglass reinforced polyester body with polycarbonate diffuser.
- Range of Cable and Wiring options
|
|
|
|
|
ECOLUX 6600
Zones 2, 21 & 22 Non-Sparking Standard or Emergency
|
- ATEX Ex II 2D, Ex II 3G, Ex II 3D, EExnA II T4
- IP66
- Certified Temperature: (18 & 36W) -20C to +55C or (58W) +45C
- Single or Twin 18/20w, 36/40W or 58/65w
- Standard ballast (Indoors) use) 198 to 264 Vac 50/60 Hz, 154 to 250 Vdc
- 1 or 2 channel Ballast(Outdoors) 220 to 254Vac ,110-127Vac,50/60 Hz.
- Polyester resin glass fibre enclosure with polycarbonate cover.
|
|
|
|

300
SERIES
Zones 2 & 22
Restricted Breathing
Standard or Emergency
|
- ATEX Ex II 3G, ATEX Ex II 3D, EExnR II T4-T6
- IP65/67
- Certified Temperature: -20C to +50C
- Single or Twin 18, 36 or 58W
- 220-240V Normal & Emergency version
- 110/127 - 220/240V Bi-Pin Version
- Fibreglass reinforced polyester body with polycarbonate diffuser.
- "Heavy Duty" version available.
|
|
|
|
|
EXEN SERIES
Zone 2 Restricted Breathing Standard or Emergency
|
- ATEX Ex II 3G, EExn II T4 certified
- IP65
- Certified Temperature: Ta @ -40C to +55C
- Single 36 & 58W, Twin 18, 36 & 58w, Twin Emergency 36 & 58W
- 220-250V, 50/60 Hz
- GRP Body with Polycarbonate Diffuser.
|
|
| |