HEATERS & THERMOSTATS
|
|
 |
FLR RADIATOR Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd IIC T6
- IP66
- 24 V single phase as standard
- 1, 2 or 2 Kw
- Ambient Temperatures up to +40C
- Lightweight cast aluminium enclosure (finished in red). Lightweight pressed steel radiator (finished in white).
- Floor mounting.
|
|
|
|  |
FAW AIR WARMER
Zones 1 & 2
Increased Safety
|
-
ATEX Ex II 2G, EExe IIC T2-T4
-
IP66/67
-
Suitable for single or 3-phase (3 or 4 wire) ac & dc power supplies.
-
Standard & compact models - from 250w to 3Kw
-
Certified Temperature: -20C to +60C
-
Coated mild steel or lightweight stainless steel enclosure
-
Floor or wall mounting.
|
|
|
|  |
CREx SWITCH CABINET HEATER
Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd IIC T4/T5
- IP65
- Voltage: 230-240 Vac, 50/60Hz or 110 Vac
- 50 or 100w
- Black anodised aluminium body with high performance heating cartridge.
- Designed for use in EX switch, control & measurement enclosures for the prevention of condensation, protection against frost and temperature fluctuations.
- may be used in conjunction with REx Thermostat control.
|
|
|
|  |
RFA ROD TYPE IMMERSION HEATER Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd IIC T1-T6
- IP67
- Ambient temperatures to -40C
- uP TO 690v. Maximum load 24Kw.
- Up to 3 rod-type elements
- Material: Lightweight cast aluminium alloy
- Choice of 'Direct-on' or 'Stand-off'.
|
|
|
|
 |
FP ROD TYPE IMMERSION HEATER Zones 1, 2, 21 & 22 Flameproof
|
- ATEX Ex II 2G/D, EExd IIC T1-T6
- IP66 & IP67
- uP TO 690v.
- Material: Low temperature carbon steel or 316L stainless steel enclosure.
- Ceramic core type elements - individually replaceable (replacement can be achived without draining the vessel)
|
|
|
|
 |
REx THERMOSTAT
Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd IIC T6
- IP65
- uP TO 250Vac max, 100 Vdc max.
- Material: Black anodised aluminium.
- Designed for temperature regulation & monitoring of heaters ef in transmiter cabinets, control panels and measuring equipment.
|
|
|
|  |
HFT AIR SENSING THERMOSTAT Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd IIC T6
- IP67
- Certified Temperature: -20C to +60C
- Rating: SPST, 16a 380v maximum
- Cast stainless steel enclosure.
- Controls: choice of 0 to 40C or 0 to 60C.
|
|
|
|  |
RFT PROCESS SENSING THERMOSTAT Zones 1 & 2 Flameproof
|
- ATEX Ex II 2G, EExd IIC t1-T6
- IP67
- Certified Temperature: -20C to +40C
- Rating: 16a, 380v maximum (choice of switching configurations)
- Lightweight cast aluminium enclosure.
- Suitable for use in process tanks and vessels containing liquids or gases.
|
|
| |