UNCERTIFIED SIGNALLING AND ALARM PRODUCTS
|
|
|
DB14 SPEAKER
for Harsh/Industrial/Marine Environments
117dB(A) max 15 Watts
|
- IP66 & IP67
- Ambient Temperature: -55C to +70C
- Corrosion-free Grey GRP body
- Output: 107 dB(A) @ 1W @ 1m
- Output: 119 dB(A) @ 15W @ 1m
- Transformer: 100V
- Tappings: 15,7.5, 5, 4, 2, 0.8
|
|
|
|
|
DB15 SOUNDER
for Harsh/Industrial/Marine Environments 117 dB(A) max
|
- 27 Selectable tones + 5 programmable
- 12, 24 and 48 Vdc, 100, 220, 254 Vac
- Ambient Temperature: -55C to +70C
- IP66 & IP67
- Corrosion-free GRP body. Natural grey finish or painted as required.
- DP15P 2-Stage unit (dc only) switchable bu reversing the supply polarity
or by 3-wire +ve system switching between two -ve line.
- Earth continuity and EOL resistor options.
|
|
|
|
|
Y08 & YL8
SOUNDER OR SOUNDER/BEACON COMBINATION
116 dB(A) max or (Super) 120 dB(A) max 2.5 or 5 Joule
|
- 2-Stage alarm with 32 selectable tones
- 24Vdc (12-35Vdc), 48 Vdc, 115 Vac, 230 Vac
- Operating Temperature: -25C to +55C
- IP54 as standard; IP65 to order
- Red Flame-Retardant ABS Plastic Enclosure
- 3 wire polarised DC & AC, or 2 wire bi-polar for DC only.
- Independently selectable 2nd Stage
|
|
|
|
|
DB12 SOUNDER
for Harsh/Industrial/Marine Environments 110 dB(A) max
|
- 27 Selectable tones + 5 programmable
- 12 and 24 Vdc
- Ambient Temperature: -55C to +70C
- IP66 & IP67
- Red corrosion-free GRP body
- Any two tones may be switched by the external supply voltage
|
|
|
|
|
Y05 & YL5
SOUNDER OR SOUNDER/BEACON COMBINATION
110 dB(A) max
|
- 2-Stage Alarm with 32 selectable tones & Volume Control
- 24Vdc (12-35Vdc), 48 Vdc, 115 Vac, 230 Vac
- Multivoltage BT Circuit 24 Vdc or 48 Vdc, 110 Vdc
- Operating Temperature: -25C to +55C
- IP54 as standard; IP65 to order
- Red Flame-Retardant ABS Plastic Enclosure
- 3 wire polarised DC (not multivoltage) & AC, or 2 wire bi-polar for DC only.
- Optional independent 2nd Stage via 2nd DIL switch
|
|
|
|
|
Y04 & YL4
SOUNDER OR SOUNDER/BEACON COMBINATION 106 dB(A) max 2.5 or 5 Joule
|
- 2-Stage alarm with 32 selectable tones & Volume Control
- 24Vdc (12-35Vdc), 48 Vdc, 115 Vac, 230 Vac
- Multivoltage BT Circuit 24 Vdc or 48 Vdc, 110 Vdc
- Operating Temperature: -25C to +55C
- IP54 as standard; IP65 to order
- Red Flame-Retardant or Red/White Non-Flame Retardant ABS Plastic Enclosure
- 3 wire polarised DC (not multivoltage) & AC, or 2 wire bi-polar for DC only.
- Optional independent 2nd Stage via 2nd DIL switch
|
|
|
|
|
WIG-WAG SOUNDER / BEACON
106 dB(A) max /
2.5 or 5 Joule
|
- Versatile triple combination unit
- Independent strobe control & sounder or alternate strobe and sounder
- 32 Selectable Tones
- 24Vdc
- Operating Temperature: -25C to +55C
- IP54 as standard; IP65 to order
- Red Flame Retardant or Red/White non-Flame Retardant ABS Plastic Enclosure
- Choice of 6 lens colours
- Optional independent 2nd Stage via 2nd DIL switch(DC)
|
|
|
|
|
CARILLON
Electronic Sounder 104 dB(A) max
|
- 32 selectable tones & Volume Control
- 24Vdc (12-35Vdc)
- Operating Temperature: -25C to +40C
- IP65
- 2-stage alarm by 2 wire bi-polar and 3 wire polarised control
|
|
|
|
|
LC32 FIRE ALARM SOUNDER
102 dB(A) max
|
- 2-Stage Alarm with 32 Selectable tones & Volume Control
- 24Vdc (12-35Vdc)
- Operating Temperature: -25C to +55C
- IP54, IP65 to order
- Red or white non-flame-retardant enclosure
- Flush or surface mounting
- Sound Selection via 5-way DIL switch
|
|
|
|
|
Y03 SOUNDER ALARM
100 dB(A) max
|
- 2-Stage alarm with 32 selectable tones & Volume control
- 24Vdc (12-35Vdc), 48 Vdc, 115 Vac, 230 Vac
- Multivoltage BT Circuit, 24 or 48 Vdc, or 110 Vdc
- Operating Temperature: -25C to +55C
- IP54 as standard; IP65 to order
- Flame-Retardant ABS Plastic Enclosure.
- 3 wire polarised DC(not multivoltage) & AC, or 2 wire bi-polar for DC only
- Optional independent 2nd Stage via 2nd DIL switch
|
|
|
|
|
YL2 SOUNDER / BEACON
100 dB(A) max
|
- Fully integrated Sounder Strobe combination unit
- Suitable for indoor use only
- 32 Selectable tones (with volume control)
- 24Vdc (+/- 20%)
- Operating Temperature: -25C to +40C
- IP54
- Red or white non-flame-retardant high impact ABS enclosure
- Light output 40 candela / Flash Rate 1 p/s
- Sound Selection via DIL switch
|
|
|
|
|
LC
SOUNDER
Electronic Sounder 100 dB(A) max
|
- choice of 2 sound signals
- 24Vdc (12-35Vdc)
- Operating Temperature: -25C to +55C
- IP54
- Red or white non-flame-retardant enclosure
- Flush or surface mounting
|
|
|
|
|
FP
QUADALARM
96 dB(A) max |
- Choice of 4 sound signals
- 24Vdc (12-30Vdc)
- Operating Temperature: -30C to +55C
- IP44
- Red or white non-flame-retardant enclosure
- General purpose sounder for indoor use only
- Suitable as bedhead alarm
|
|
|
|
|
XB13 XENON BEACON
10 Joule
|
- Operating Temperature: -40C to +70C
- IP66 & IP67
- 12 or 24 Vdc, 115 or 230 Vac
- Corrosion-free GRP body and Polycarbonate lens (Red or Amber)
- 60 Flashes per minute as standard
- Switchable dual flash, Telephone & relay initiate options.
|
|
|
|
|
V4 STROBE
2.5 or 5 Joule
|
- Operating Temperature: -25C to +40C
- IP65
- 12, 24 or 48 Vdc, 115 Vac, 230 Vac
- Red Flame-Retardant or red/white Non-Flame Retardant ABS Plastic Enclosure
- High flashing Intensity - Flash Rate 1 p/s
- 360 degree visibility
- Complements Audible Alarm System
|
|
|
|
|
V4S FILAMENT LAMP INDICATOR
3.5 or 4.5 Joule
|
- General purpose indicator for indoor use only
- 12 or 24 Vdc, 115 Vac, 230 Vac
- Operating Temperature: -25C to +40C
- IP44
- Red Flame-Retardant or Red/White Non-Flame Retardant Enclosure
- Choice of 6 Lens colours
- Life Expectancy 1000 -5000 hours
|
|
|
|
|
DOOR HOLDER
Electromagnetic |
- Holding Force 11.3Kg
- For Indoor Use only
- IP44
- 24Vdc, 230 Vac 50/60 Hz
- Operating Temperature: -25C to +55C
- Integral Reset
- Test/override button
- Electrically released in the event of fire
|
|
| |