Select a subcategory from below, or browse through your selection.
Emergency Lighting, suitable for all your hazardous area needs, includes a range from ATEX, IECEx, GOST R, GOST K and INMETRO certifications suitable for zone 1, 2, 21 & 22.
![]() |
![]() |
FEAM EVFGE
EMERGENCY FLUORESCENT LUMINAIRE
EMERGENCY FLUORESCENT LUMINAIRE
Zones: 1, 2, 21, 22
Ex II 2 G/D
Ex d IIC T6 Gb
Ex tb IIIC T85ºC Db
ATEX, IECEx, INMETRO, GOST 'R', GOST 'K'
Ex II 2 G/D
Ex d IIC T6 Gb
Ex tb IIIC T85ºC Db
ATEX, IECEx, INMETRO, GOST 'R', GOST 'K'
- Supply Voltage: Electronic ballast 110V/260V - 50/60Hz
- Body: Marine grade copper free aluminium with high-temperature resistant borosilicate glass tube
- Cable Entry: 2 x 3/4" NPT
- Lamp Holder: Bi-Pin G13 Cap
- Ingress Protection: IP66
- Lamp Ratings: 2 x 18W, 2 x 36W, 2 x 58W (Lamps Not Included)
- Emergency Unit: 4.8V - 4Ah
- Autonomy: 120 minutes (3hrs available on request)
![]() |
![]() |
FEAM AVCE
EMERGENCY FLUORESCENT LUMINAIRE
EMERGENCY FLUORESCENT LUMINAIRE
Zones: 1, 2, 21, 22
Ex II G/D
Ex d e q IIC T4 Gb
Ex tD IIIC T80°C Db
ATEX, IECEx, INMETRO, GOST 'R'
Ex II G/D
Ex d e q IIC T4 Gb
Ex tD IIIC T80°C Db
ATEX, IECEx, INMETRO, GOST 'R'
- Supply Voltage: 96/254V AC 50/60Hz
- Body: Black GRP
- Cable Entry: 4 x M25 (2 at each end)
- Lamp Holders: bi-pin G13 cap
- Lamp Ratings: 2 x 18W, 2 x 36W (lamps not included)
- Emergency Unit: 4.8V - 4Ah
- Autonomy: 3h
- Terminals: Suitable up to 4sq/mm cables
- Ingress Protection: IP66
- Ambient Temperature: -20°C to +60°C
![]() |
![]() |
FEAM EVSNE
EMERGENCY FLUORESCENT LUMINAIRE
EMERGENCY FLUORESCENT LUMINAIRE
Zones: 2, 22
Ex II 3 G/D
Ex nA II T6/T5/T4
Ex tD A22 T85ºC/T100ºC/T135ºC
ATEX, IECEx, INMETRO, GOST 'R'
Ex II 3 G/D
Ex nA II T6/T5/T4
Ex tD A22 T85ºC/T100ºC/T135ºC
ATEX, IECEx, INMETRO, GOST 'R'
- Supply Voltage: Dual channel electronic ballast 110 to 260V AC/DC 50/60Hz
- Body: GRP
- Ingress Protection: IP65/66
- Cable Entry: 2 x M20 (1 at each end)
- Lamp Holder: Bi-Pin G13 cap
- Lamp Ratings: 2 x 18W, 2 x 36W, 2 x 58W (lamps not included)
- Terminals: Suitable up to 6 sq/mm cable
- Emergency Unit: 4.8V - 4Ah
- Autonomy: 3h
![]() |
![]() |
PETREL 9 SERIES
FLUORESCENT LUMINAIRE
FLUORESCENT LUMINAIRE
Zones: 1, 2
EEx ed IIC T5 – T4
ATEX
EEx ed IIC T5 – T4
ATEX
- Protection IP 65
- Integral isolation switch as standard
- Single point locking action
- EOL lamp shut down
- High light output
- Integral battery with 3 hr. duration on emergency versions
- Alternative voltages
- Through wiring
- Omission of isolation switch
![]() |
![]() |
PETREL EXEN
FLUORESCENT LUMINAIRE
FLUORESCENT LUMINAIRE
Zones: 2
EEx nC II T4
ATEX
EEx nC II T4
ATEX
- Protection IP 65
- Unrestricted breathing
- No vacuum test required
- Integral battery with 3hr duration on emergency versions
- Closed cell gasket
- Push fit gear tray
- Stainless steel clips
![]() |
![]() |
PETREL 7 SERIES
EMERGENCY FLUORESCENT LUMINAIRE
EMERGENCY FLUORESCENT LUMINAIRE
Zones: 1
Ex d IIB or IIC T5 or T4
ATEX
Ex d IIB or IIC T5 or T4
ATEX
- Protection IP 66
- Internally mounted batteries giving 3 hr duration
- EOL lamp protection
- 50,000 hour electronic ballast
- Wide range of voltage options
- Large range of lamp options
- IP68 versions
![]() |
![]() |
PETREL 9R SERIES
RECESSED FLUORESCENT LUMINAIRE
RECESSED FLUORESCENT LUMINAIRE
Zones: 1, 2
Ex de IIC T5 – T4
ATEX
Ex de IIC T5 – T4
ATEX
- Protection IP 55
- Flush fitting – minimizing dust build up
- EOL lamp shut down
- Integral battery with 3hr duration on emergency versions
- Alternative voltages
- Through wiring
- Omission of isolation switch